Proximity Sensor DC 3-wire/DC 2-wire

E2EQ NEXT

Enables easier and standardized designs previously not possible with fluororesin coating models

BASIC Model

E2EQ NEXT Series (Spatter-resistant Double distance/Single distance model)

DC 3-wire Shielded

Types

Double distance Models

Size

M8

M12

M18

M30

Model

E2EQ-X2[]8

E2EQ-X4[]12

E2EQ-X8[]18

E2EQ-X15[]30

Sensing distance

2 mm±10%

4 mm±10%

8 mm±10%

15 mm±10%

Setting distance

0 to 1.6 mm

0 to 3.2 mm

0 to 6.4 mm

0 to 12 mm

Differential travel

15% max. of sensing distance

Detectable object

Ferrous metals (For non-ferrous metals, refer to the Engineering Data on Catalog.)

Standard sensing object (Iron)

8 × 8 × 1 mm

12 × 12 × 1 mm

24 × 24 × 1 mm

45 × 45 × 1 mm

Response frequency *1

1,500 Hz

1,000 Hz

500 Hz

250 Hz

Power supply voltage

10 to 30 VDC (including 10% ripple (p-p)), Class 2

Current consumption

1-output models: 16 mA max., 2-output models: 20 mA max.

Output configuration

B[] Models: PNP open collector, C[] Models: NPN open collector

Operation mode
 (with sensing object
 approaching)

1-output models (B1, C1): NO (Normally open),
 1-output models (B2, C2): NC (Normally closed)
 2-output models (B3, C3): NO+NC (Normally open, Normally closed)

Control
 output

Load current

M8 size
 1-output models: 10 to 30 VDC, Class 2, 200 mA max., (-40 to 70°C), 100 mA max., (70
 to 85°C)
 2-output models: 10 to 30 VDC, Class 2, 50 mA max.
 M12, M18, M30 size
 1-output models: 10 to 30 VDC, Class 2, 200 mA max., 2-output models:10 to 30 VDC,
 Class 2, 100 mA max.

Residual voltage

M8 size
 1-output models: 2 V max. (Load current: 200 mA, Cable length: 2 m), 2-output models:
 2 V max. (Load current: 50 mA, Cable length: 2 m)
 M12, M18, M30 size
 1-output models: 2 V max. (Load current: 200 mA, Cable length: 2 m), 2-output models:
 2 V max. (Load current: 100 mA, Cable length: 2 m)

Indicator *2

In the Standard I/O mode (SIO mode): Operation indicator (orange, lit) and
 communication indicator (green, not lit)
 In the IO-Link communication mode (COM mode): Operation indicator (orange, lit) and
 communication indicator (green, blinking at 1 s intervals)

Protection circuits

Power supply reverse polarity protection, Surge suppressor, Output short-circuit
 protection, Output reverse polarity protection

Ambient temperature range

Operating/Storage: -40 to 85°C (with no icing or condensation)
 Note: The UL temperature rating for M12 Pre-wired Connector Models is -25 to 70°C.

Ambient humidity range

Operating/Storage: 35% to 95% (with no condensation)

Temperature influence

±15% max. of sensing distance at 23°C in the temperature range of -40 to 85°C
 ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C

Voltage influence

±1% max. of sensing distance at rated voltage in the rated voltage ±15% range

Insulation resistance

50 MΩ min. (at 500 VDC) between current-carrying parts and case

Dielectric strength

1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case

Vibration resistance
 (destruction)

10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions

Shock resistance
 (destruction)

M8 size: 500 m/s2 10 times each in X, Y, and Z directions/
M12, M18, M30 size: 1,000 m/s2 10 times each in X, Y, and Z directions

Degree of protection

Pre-wired Models, Pre-wired Connector Models: IEC 60529:IP67, JIS C 0920 Annex 1:
 IP67G *4/Connector Models: IEC 60529 IP67

Connection method

Pre-wired Models (Standard cable length: 2 m) and Pre-wired Connector Models
 (Standard cable length: 0.3 m), M12 Connector Models

Weight *3
 (packed
 state)

Pre-wired

Approx. 85 g

Approx. 95 g

Approx. 170 g

Approx. 240 g

M12 Pre-wired
 Smartclick
 Connector

Approx. 55 g

Approx. 70 g

Approx. 105 g

Approx. 170 g

Connector

Approx. 40 g

Approx. 55 g

Approx. 85 g

Approx. 160 g

Materials

Case

M8 size: Fluororesin coating (Base material: SUS303)/
 M12, M18, M30 size: Fluororesin coating (Base material: brass)

Sensing surface

Fluorine resin

Clamping nuts

Fluororesin coating (Base material: brass)

Toothed washers

Zinc-plated iron

Cable

Vinyl chloride (PVC)

Main IO-Link functions *2

Operation mode switching between NO and NC, self diagnosis enabling, excessive
 proximity judgment distance selecting, timer function of the control output and timer time
 selecting, instability output (IO-Link mode) ON delay timer time selecting function,
 monitor output, operating hours read-out, readout of the sensor internal temperature,
 and initial reset

IO-Link
 Commun-
 ication
 specifica-
 tions *2

IO-Link
 specification

Ver1.1

Baud rate

COM2 (38.4 kbps), COM3 (230.4 kbps)

Data length

PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE_2_2)

Minimum cycle
 time

COM2: 2.3 ms, COM3: 0.4 ms

Accessories

Instruction manual, Clamping nuts, Toothed washer

Types

Single distance Models

Size

M8

M12

M18

M30

Model

E2EQ-X1R5[]8

E2EQ-X2[]12

E2EQ-X5[]18

E2EQ-X10[]30

Sensing distance

1.5 mm±10%

2 mm±10%

5 mm±10%

10 mm±10%

Setting distance

0 to 1.2 mm

0 to 1.6 mm

0 to 4 mm

0 to 8 mm

Differential travel

15% max. of sensing distance

Detectable object

Ferrous metals (For non-ferrous metals, refer to the Engineering Data on Catalog.)

Standard sensing object (Iron)

8 × 8 × 1 mm

12 × 12 × 1 mm

18 × 18 × 1 mm

30 × 30 × 1 mm

Response frequency *1

2,000 Hz

1,500 Hz

600 Hz

400 Hz

Power supply voltage

10 to 30 VDC (including 10% ripple (p-p)), Class 2

Current consumption

1-output models: 16 mA max., 2-output models: 20 mA max.

Output configuration

B[] Models: PNP open collector, C[] Models: NPN open collector

Operation mode
 (with sensing object
 approaching)

1-output models (B1, C1): NO (Normally open),
 1-output models (B2, C2): NC (Normally closed)
 2-output models (B3, C3): NO+NC (Normally open, Normally closed)

Control
 output

Load current

M8 size
 1-output models: 10 to 30 VDC, Class 2, 200 mA max., (-40 to 70°C), 100 mA max., (70
 to 85°C)
 2-output models: 10 to 30 VDC, Class 2, 50 mA max.
 M12, M18, M30 size
 1-output models: 10 to 30 VDC, Class 2, 200 mA max., 2-output models:10 to 30 VDC,
 Class 2, 100 mA max.

Residual voltage

M8 size
 1-output models: 2 V max. (Load current: 200 mA, Cable length: 2 m), 2-output models:
 2 V max. (Load current: 50 mA, Cable length: 2 m)
 M12, M18, M30 size
 1-output models: 2 V max. (Load current: 200 mA, Cable length: 2 m), 2-output models:
 2 V max. (Load current: 100 mA, Cable length: 2 m)

Indicator *2

In the Standard I/O mode (SIO mode): Operation indicator (orange, lit) and
 communication indicator (green, not lit)
 In the IO-Link communication mode (COM mode): Operation indicator (orange, lit) and
 communication indicator (green, blinking at 1 s intervals)

Protection circuits

Power supply reverse polarity protection, Surge suppressor, Output short-circuit
 protection, Output reverse polarity protection

Ambient temperature range

Operating/Storage: -40 to 85°C (with no icing or condensation)
 Note: The UL temperature rating for M12 Pre-wired Connector Models is -25 to 70°C.

Ambient humidity range

Operating/Storage: 35% to 95% (with no condensation)

Temperature influence

±15% max. of sensing distance at 23°C in the temperature range of -40 to 85°C
 ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C

Voltage influence

±1% max. of sensing distance at rated voltage in the rated voltage ±15% range

Insulation resistance

50 MΩ min. (at 500 VDC) between current-carrying parts and case

Dielectric strength

1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case

Vibration resistance
 (destruction)

10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions

Shock resistance
 (destruction)

M8 size: 500 m/s2 10 times each in X, Y, and Z directions/
M12, M18, M30 size: 1,000 m/s2 10 times each in X, Y, and Z directions

Degree of protection

Pre-wired Models, Pre-wired Connector Models: IEC 60529:IP67, JIS C 0920 Annex 1:
 IP67G *4/Connector Models: IEC 60529 IP67

Connection method

Pre-wired Models (Standard cable length: 2 m) and Pre-wired Connector Models
 (Standard cable length: 0.3 m), M12 Connector Models

Weight *3
 (packed
 state)

Pre-wired

Approx. 85 g

Approx. 95 g

Approx. 170 g

Approx. 240 g

M12 Pre-wired
 Smartclick
 Connector

Approx. 55 g

Approx. 70 g

Approx. 105 g

Approx. 170 g

Connector

Approx. 40 g

Approx. 55 g

Approx. 85 g

Approx. 160 g

Materials

Case

M8 size: Fluororesin coating (Base material: SUS303)/
 M12, M18, M30 size: Fluororesin coating (Base material: brass)

Sensing surface

Fluorine resin

Clamping nuts

Fluororesin coating (Base material: brass)

Toothed washers

Zinc-plated iron

Cable

Vinyl chloride (PVC)

Main IO-Link functions *2

Operation mode switching between NO and NC, self diagnosis enabling, excessive
 proximity judgment distance selecting, timer function of the control output and timer time
 selecting, instability output (IO-Link mode) ON delay timer time selecting function,
 monitor output, operating hours read-out, readout of the sensor internal temperature,
 and initial reset

IO-Link
 Commun-
 ication
 specifica-
 tions *2

IO-Link
 specification

Ver1.1

Baud rate

COM2 (38.4 kbps), COM3 (230.4 kbps)

Data length

PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE_2_2)

Minimum cycle
 time

COM2: 2.3 ms, COM3: 0.4 ms

Accessories

Instruction manual, Clamping nuts, Toothed washer

1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
 2. IO-Link is not supported for NC-type PNP outputs or all types of NPN outputs.
 3. Weight of the standard body-sized model.
 4. The IP67G is the degree of protection which is defined according to the JIS (Japanese Industrial Standards).
 The IP67 indicates the same level of protection as defined by the IEC, and the G indicates that a device has resistance to oil.

E2EQ NEXT Series (Spatter-resistant Double distance model)

DC 2-wire Shielded

Size

M12

M18

M30

Model

E2EQ-X4D[]12

E2EQ-X8D[]18

E2EQ-X15D[]30

Sensing distance

4 mm ±10%

8 mm ±10%

15 mm ±10%

Setting distance *1

0 to 3.2 mm

0 to 6.4 mm

0 to 12 mm

Differential travel

15% max. of sensing distance

Detectable object

Ferrous metals (For non-ferrous metals, refer to Engineering Data on Catalog.)

Standard sensing object (Iron)

12 × 12 × 1 mm

18 × 18 × 1 mm

30 × 30 × 1 mm

Response frequency *2

1,000 Hz

500 Hz

250 Hz

Power supply voltage

10 to 30 VDC (including 10% ripple (p-p)), Class 2

Current consumption

0.8 mA max.

Control
 output

Load current

3 to 100 mA

Residual voltage

5 V max. (Load current: 100 mA, Cable length: 2 m)

Indicator

Operation indicator (orange), Setting indicator (green)

Operation mode

NO
 Refer to the timing charts under I/O Circuit Diagrams/Timing charts on Catalog for
 details.

Protection circuits

Surge suppressor, Load short-circuit protection

Ambient temperature range

Operating: -25 to 70°C, Storage: -40 to 85°C (with no icing or condensation)

Ambient humidity range

Operating and Storage: 35% to 95% (with no condensation)

Temperature influence

±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C

Voltage influence

±1% max. of sensing distance at rated voltage in the rated voltage ±15% range

Insulation resistance

50 MΩ min. (at 500 VDC) between current-carrying parts and case

Dielectric strength

1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case

Vibration resistance (destruction)

10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions

Shock resistance (destruction)

1,000 m/s2 10 times each in X, Y, and Z directions

Degree of protection

Pre-wired Models, Pre-wired Connector Models: IEC 60529:IP67, JIS C 0920 Annex
 1: IP67G

Connection method

Pre-wired Models (Standard cable length: 2 m) and
 M12 Pre-wired Smartclick Connector Models (Standard cable length: 0.3 m)

Weight
 (packed
 state)

Pre-wired

Approx. 100 g

Approx. 180 g

Approx. 250 g

M12 Pre-wired
 Smartclick
 Connector

Approx. 75 g

Approx. 110 g

Approx. 180 g

Materials

Materials

Fluororesin coating (Base material: brass)

Sensing surface

Fluororesin

Clamping nuts

Fluororesin coating (Base material: brass)

Toothed washer

Zinc-plated iron

Cable

Vinyl chloride (PVC)

Accessories

Instruction manual, Clamping nuts, Toothed washer

1. Use the Sensor within the range in which the setting indicator (green LED) is ON.
 2. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.

PREMIUM Model

E2EQ NEXT Series (Spatter-resistant Triple distance model)

DC 3-wire Shielded

Size

M8

M12

M18

M30

Model

E2EQ-X3[]8

E2EQ-X6[]12

E2EQ-X12[]18

E2EQ-X22[]30

Sensing distance

3 mm±10%

6 mm±10%

12 mm±10%

22 mm±10%

Setting distance

0 to 2.4 mm

0 to 4.8 mm

0 to 9.6 mm

0 to 16.8 mm

Differential travel

15% max. of sensing distance

Detectable object

Ferrous metals (For non-ferrous metals, refer to the Engineering Data on Catalog.)

Standard sensing object (Iron)

9 × 9 × 1 mm

18 × 18 × 1 mm

36 × 36 × 1 mm

66 × 66 × 1 mm

Response frequency *1

1,000 Hz

800 Hz

500 Hz

200 Hz

Power supply voltage

10 to 30 VDC (including 10% ripple (p-p)), Class 2

Current consumption

1-output models:
 16 mA max.

1-output models: 16 mA max., 2-output models: 20 mA max.

Output configuration

B[] Models: PNP open collector, C[] Models: NPN open collector

Operation mode
 (with sensing object
 approaching)

1-output models (B1,
 C1): NO (Normally
 open),
 1-output models (B2,
 C2): NC (Normally
 closed)

1-output models (B1, C1): NO (Normally open),
 1-output models (B2, C2): NC (Normally closed),
 2-output models (B3, C3): NO+NC (Normally open, Normally
 closed)

Control
 output

Load current

1-output models: 10 to
 30 VDC, Class 2, 100
 mA max.

1-output models: 10 to 30 VDC, Class 2, 100 mA max.,,
 2-output models: 10 to 30 VDC, Class 2, 50 mA max.

Residual voltage

1-output models: 2 V
 max. (Load current:
 100 mA, Cable length:
 2 m)

1-output models: 2 V max. (Load current: 100 mA, Cable
 length: 2 m),
 2-output models: 2 V max. (Load current: 50 mA, Cable
 length: 2 m)

Indicator *2

In the Standard I/O mode (SIO mode): Operation indicator (orange, lit) and
 communication indicator (green, not lit)
 In the IO-Link communication mode (COM mode): Operation indicator (orange, lit) and
 communication indicator (green, blinking at 1 s intervals)

Protection circuits

Power supply reverse polarity protection, Surge suppressor, Output short-circuit
 protection, Output reverse polarity protection

Ambient temperature range

Operating/Storage: -25 to 70°C (with no icing or condensation)

Ambient humidity range

Operating/Storage: 35% to 95% (with no condensation)

Temperature influence

±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C

Voltage influence

±1% max. of sensing distance at rated voltage in the rated voltage ±15% range

Insulation resistance

50 MΩ min. (at 500 VDC) between current-carrying parts and case

Dielectric strength

1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case

Vibration resistance
 (destruction)

10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions

Shock resistance
 (destruction)

500 m/s2 10 times
 each in X, Y, and Z
 directions

1,000 m/s2 10 times each in X, Y, and Z directions

Degree of protection

Pre-wired Models, Pre-wired Connector Models: IEC 60529: IP67, JIS C 0920 Annex 1:
 IP67G *4
 Connector Models: IEC 60529: IP67

Connection method

Pre-wired Models (Standard cable length: 2 m) and Pre-wired Connector Models
 (Standard cable length: 0.3 m), M12 Connector Models

Weight *3
 (packed
 state)

Pre-wired

Approx. 85 g

Approx. 95 g

Approx. 180 g

Approx. 260 g

M12 Pre-wired
 Smartclick
 Connector

Approx. 55 g

Approx. 70 g

Approx. 115 g

Approx. 200 g

Connector

Approx. 40 g

Approx. 55 g

Approx. 95 g

Approx. 180 g

Materials

Case

Fluororesin coating (Base material: brass)

Sensing surface

Fluorine resin

Clamping nuts

Fluororesin coating (Base material: brass)

Toothed washers

Zinc-plated iron

Cable

Vinyl chloride (PVC)

Main IO-Link functions *2

Operation mode switching between NO and NC, self diagnosis enabling, excessive
 proximity judgment distance selecting, timer function of the control output and timer time
 selecting, instability output (IO-Link mode) ON delay timer time selecting function,
 monitor output, operating hours read-out, readout of the sensor internal temperature,
 and initial reset

IO-Link
 Commun-
 ication
 specifica-
 tions *2

IO-Link
 specification

Ver 1.1

Baud rate

COM2 (38.4 kbps), COM3 (230.4 kbps)

Data length

PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE_2_2)

Minimum cycle
 time

COM2: 2.3 ms, COM3: 0.4 ms

Accessories

Instruction manual, Clamping nuts, Toothed washer

1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
 2. IO-Link is not supported for NC-type PNP outputs or all types of NPN outputs.
 3. Weight of the standard body-sized model.
 4. The IP67G is the degree of protection which is defined according to the JIS (Japanese Industrial Standards).
 The IP67 indicates the same level of protection as defined by the IEC, and the G indicates that a device has resistance to oil.

E2EQ NEXT Series (Spatter-resistant Triple distance model)

DC 2-wire Shielded

Size

M8

M12

M18

M30

Model

E2EQ-X3D[]

E2EQ-X7D[]

E2EQ-X11D[]

E2EQ-X20D[]

Sensing distance

3 mm ±10%

7 mm ±10%

11 mm ±10%

20 mm ±10%

Setting distance *1

0 to 2.4 mm

0 to 4.9 mm

0 to 8.8 mm

0 to 16 mm

Differential travel

15% max. of sensing distance

Detectable object

Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to
 Engineering Data on Catalog.)

Standard sensing object
 (Iron)

9 × 9 × 1 mm

21 × 21 × 1 mm

33 × 33 × 1 mm

60 × 60 × 1 mm

Response frequency *2

250 Hz

250 Hz

250 Hz

200 Hz

Power supply voltage

10 to 30 VDC, (including 10% ripple (p-p))

Leakage current

0.8 mA max.

Control
 output

Load current

3 to 100 mA

Residual
 voltage

Polarity: 3 V max. (Load current: 100 mA, Cable length: 2 m)
 No polarity: 5 V max. (Load current: 100 mA, Cable length: 2 m)

Indicator

D1 Models: Operation indicator (orange), Setting indicator (green)
 D2 Models: Operation indicator (orange)

Operation mode

D1 Models: NO
 D2 Models: NC
 Refer to the timing charts under I/O Circuit Diagrams/Timing charts on Catalog for details.

Protection circuits

Surge suppressor, Load short-circuit protection

Ambient temperature
 range

Operating: -25 to 70°C, Storage: -40 to 85°C (with no icing or condensation)

Ambient humidity range

Operating and Storage: 35% to 95% (with no condensation)

Temperature influence

±10% max. of sensing distance at 23°C
 in the temperature range of -25 to 70°C

±20% max. of sensing distance at 23°C
 in the temperature range of -25 to 70°C

Voltage influence

±1% max. of sensing distance at rated voltage in the rated voltage ±15% range

Insulation resistance

50 MΩ min. (at 500 VDC) between current-carrying parts and case

Dielectric strength

1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case

Vibration resistance
 (destruction)

10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions

Shock resistance
 (destruction)

500 m/s2 10 times
 each in X, Y, and Z
 directions

1,000 m/s2 10 times each in X, Y, and Z directions

Degree of protection

Pre-wired/Pre-wired M12 Connector: IP67 (IEC 60529) and IP67G *3 (JIS C 0920 Annex 1)

Connecting method

Pre-wired (Standard cable length: 2 m) and Pre-wired M12 Connector (Standard cable
 length: 0.3 m)

Weight
 (packed
 state)

Pre-wired
 Models

Approx. 60 g

Approx. 70 g

Approx. 150 g

Approx. 210 g

Pre-wired
 M12
 Connector

Approx. 30 g

Approx. 40 g

Approx. 90 g

Approx. 140 g

Materials

Case

Fluororesin coating (Base material: brass)

Sensing
 surface

Fluororesin

Clamping
 nuts

Fluororesin coating (Base material: brass)

Toothed
 washer

Zinc-plated iron

Cable

Vinyl chloride (PVC)

Accessories

Instruction manual, Clamping nuts, Toothed washer

1. Use the Sensor within the range in which the setting indicator (green LED) is ON (except D2 Models).
 2. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
 3. The IP67G is the degree of protection which is defined according to the JIS (Japanese Industrial Standards). 

The IP67 indicates the same level of protection as defined by the IEC, and the G indicates that a device has resistance to oil.