Chemical-resistant Proximity Sensor

E2FQ

Inductive Proximity Sensor with Chemical-resistant Fluororesin Case

Model

E2FQ-X2E1
 E2FQ-X2D1

E2FQ-X5E1
 E2FQ-X5D1, E2FQ-X5Y1

E2FQ-X10E1
 E2FQ-X10D1, E2FQ-X10Y1

Sensing distance

2 mm ±10%

5 mm ±10%

10 mm ±10%

Set distance

0 to 1.6 mm

0 to 4 mm

0 to 8 mm

Differential travel

E1/Y1 Models: 10% max. of sensing distance, D1 Models: 20% max. of sensing distance

Detectable object

Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on Data Sheet.)

Standard sensing object

Iron, 12 × 12 × 1 mm

Iron, 18 × 18 × 1 mm

Iron, 30 × 30 × 1 mm

Response frequency *

E1 Models: 1.5 kHz
 D1 Models: 800 Hz

E1 Models: 600 Hz
 D1 Models: 500 Hz

E1 Models: 400 Hz
 D1 Models: 300 Hz

Y1 Models: 25 Hz

Power supply voltage
 (operating voltage
 range)

E1 Models: 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
 Y1 Models: 24 to 240 VAC (20 to 264 VAC), 50/60 Hz
 D1 Models: 12 to 24 VDC (10 to 36 VDC), ripple (p-p): 20% max.

Current consumption

E1 Models: 17 mA max.

Leakage current

D1 Models: 0.8 mA max., Y1 Models: 1.7 mA max. (at 200 VAC)

Control
 output

Load
 current

E1 Models: 200 mA max., D1 Models: 5 to 100 mA, Y1 Models: 5 to 300 mA

Residual
 voltage

E1 Models: 2 V max. (Load current: 200 mA, Cable length: 2 m)
 Y1 Models: Refer to Engineering Data on Data Sheet.
 D1 Models: 3 V max. (Load current: 100 mA, Cable length: 2 m)

Indicators

E Models: Detection indicator (red), Y Models: Operation indicator (red),
 D Models: Operation indicator (red), Setting indicator (green) (NO only)

Operation mode
 (with sensing object
 approaching)

E1/D1/Y1 Models: NO (Refer to the timing charts under I/O Circuit Diagrams on Data Sheet for details.)

Protection circuits

E1 Models: Load short-circuit protection, Reverse polarity protection, Surge suppressor, D1/Y1 Models: Surge suppressor

Ambient temperature
 range

Operating/Storage: -25 to 70°C (with no icing or condensation)

Ambient humidity range

Operating/Storage: 35% to 95% (with no condensation)

Temperature influence

±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C

Voltage influence

E1 Models: ±2.5% max. of sensing distance at rated voltage in the rated voltage ±15% range
 D1 Models: ±2.5% max. of sensing distance at rated voltage in the rated voltage ±20% range
 Y1 Models: ±1% max. of sensing distance at rated voltage in the rated voltage ±10% range

Insulation resistance

50 MΩ min. (at 500 VDC) between current-carrying parts and case

Dielectric strength

E1/D1 Models: 1,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case
 Y Models: 4,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case

Vibration resistance

Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions

Shock resistance

Destruction: 500 m/s2
 10 times each in X, Y,
 and Z directions

Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions

Degree of protection

IEC 60529 IP67, in-house standards: oil-resistant

Connection method

Pre-wired Models (Cable length: 2 m)

Weight (packed state)

Approx. 70 g

Approx. 130 g

Approx. 170 g

Materials

Case

Fluororesin

Sensing
 surface

Clamping
 nuts

Toothed
 washer

Zinc-plated iron

Cable

Vinyl chloride

Accessories

Instruction manual

* The response frequency is an average value.
   Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and
   a set distance of half the sensing distance.