Chemical-resistant Proximity Sensor
E2FQ
Inductive Proximity Sensor with Chemical-resistant Fluororesin Case
Model |
E2FQ-X2E1 |
E2FQ-X5E1 |
E2FQ-X10E1 |
|
Sensing distance |
2 mm ±10% |
5 mm ±10% |
10 mm ±10% |
|
Set distance |
0 to 1.6 mm |
0 to 4 mm |
0 to 8 mm |
|
Differential travel |
E1/Y1 Models: 10% max. of sensing distance, D1 Models: 20% max. of sensing distance |
|||
Detectable object |
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on Data Sheet.) |
|||
Standard sensing object |
Iron, 12 × 12 × 1 mm |
Iron, 18 × 18 × 1 mm |
Iron, 30 × 30 × 1 mm |
|
Response frequency * |
E1 Models: 1.5 kHz |
E1 Models: 600 Hz |
E1 Models: 400 Hz |
|
Y1 Models: 25 Hz |
||||
Power supply voltage |
E1 Models: 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. |
|||
Current consumption |
E1 Models: 17 mA max. |
|||
Leakage current |
D1 Models: 0.8 mA max., Y1 Models: 1.7 mA max. (at 200 VAC) |
|||
Control |
Load |
E1 Models: 200 mA max., D1 Models: 5 to 100 mA, Y1 Models: 5 to 300 mA |
||
Residual |
E1 Models: 2 V max. (Load current: 200 mA, Cable length: 2 m) |
|||
Indicators |
E Models: Detection indicator (red), Y Models: Operation indicator (red), |
|||
Operation mode |
E1/D1/Y1 Models: NO (Refer to the timing charts under I/O Circuit Diagrams on Data Sheet for details.) |
|||
Protection circuits |
E1 Models: Load short-circuit protection, Reverse polarity protection, Surge suppressor, D1/Y1 Models: Surge suppressor |
|||
Ambient temperature |
Operating/Storage: -25 to 70°C (with no icing or condensation) |
|||
Ambient humidity range |
Operating/Storage: 35% to 95% (with no condensation) |
|||
Temperature influence |
±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C |
|||
Voltage influence |
E1 Models: ±2.5% max. of sensing distance at rated voltage in the rated voltage ±15% range |
|||
Insulation resistance |
50 MΩ min. (at 500 VDC) between current-carrying parts and case |
|||
Dielectric strength |
E1/D1 Models: 1,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case |
|||
Vibration resistance |
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
|||
Shock resistance |
Destruction: 500 m/s2 |
Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions |
||
Degree of protection |
IEC 60529 IP67, in-house standards: oil-resistant |
|||
Connection method |
Pre-wired Models (Cable length: 2 m) |
|||
Weight (packed state) |
Approx. 70 g |
Approx. 130 g |
Approx. 170 g |
|
Materials |
Case |
Fluororesin |
||
Sensing |
||||
Clamping |
||||
Toothed |
Zinc-plated iron |
|||
Cable |
Vinyl chloride |
|||
Accessories |
Instruction manual |
* The response frequency is an average value.
Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and
a set distance of half the sensing distance.