Small Enclosed Switches
VE
Small, Lightweight Enclosed Switches
Ratings
Rated |
Non-inductive load (A) |
Inductive load (A) |
|||||||||
Resistive load |
Lamp load |
Inductive load |
Motor load |
||||||||
NC |
NO |
NC |
NO |
NC |
NO |
NC |
NO |
||||
125 AC |
10 |
2 |
10 |
3 |
|||||||
8 DC |
10 |
2 |
6 |
6 |
|||||||
Inrush current |
NC |
24 A max. |
|||||||||
NO |
24 A max. |
||||||||||
Note: 1. The above values are continuous currents.
2. Inductive loads have a power factor of 0.4 or higher (AC) or a time constant of 7 ms or lower (DC).
3. Lamp loads have an inrush current of 10 times the steady-state current.
4. Motor loads have an inrush current of 6 times the steady-state current.
Characteristics
Degree of protection |
IP60 |
|
Durability * |
Mechanical |
1,500,000 operations min. |
Electrical |
300,000 operations min. (10 A at 250 VAC, resistive load) |
|
Operating speed |
Sealed plunger: 0.1 mm/s to 0.5 m/s |
|
Allowable operating |
Mechanical |
120 operations/min. |
Electrical |
60 operations/min. |
|
Rated frequency |
50/60 Hz |
|
Insulation resistance |
100 MΩ min. (at 500 VDC) |
|
Contact resistance |
15 mΩ max. (initial value) |
|
Dielectric strength |
Between terminals of the |
1,000 VAC at 50/60 Hz for 1 minute |
Between each terminal and |
1,500 VAC, 50/60 Hz for 1 minute |
|
Vibration resistance |
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude |
|
Shock resistance |
Destruction: 1,000 m/s2 max., Malfunction: 300 m/s2 max. |
|
Ambient operating temperature |
-10°C to 80°C (with no icing) |
|
Ambient operating humidity |
35% to 95% |
|
Weight |
Approx. 120 to 170 g |
Note: The above values are initial values.
* The values are calculated at an operating temperature of 5°C to 35°C and an operating humidity of 40% to 70%. Contact your OMRON sales representative for more detailed information on other operating environments.
Engineering Data