Enclosed Switches
ZE / ZV / ZV2 / XE / XV / XV2
Long Service Life and Large Breaking Power
Approved Standards
Agency |
Standard |
File No. |
UL |
UL508 |
E76675 |
CSA |
CSA C22.2 No.14 |
LR45746 |
CCC (CQC) |
GB/T14048.5 |
Contact your OMRON representative for details. |
Note: 1. Models XE, XV, and XV2 are not approved by UL, CSA, and CCC.
2. Ask your OMRON representative for information on approved models.
Ratings
Model |
Rated voltage |
Non-inductive load (A) |
Inductive load (A) |
||||||
Resistive load |
Lamp load |
Inductive load |
Motor load |
||||||
NC |
NO |
NC |
NO |
NC |
NO |
NC |
NO |
||
ZE-[] |
125 VAC |
15 |
3 |
1.5 |
15 |
5 |
2.5 |
||
125 VDC |
0.5 |
0.5 |
0.05 |
0.05 |
|||||
XE-[] |
8 VDC |
10 |
3 |
1.5 |
10 |
10 |
5 |
2.5 |
|
Note: 1. The above figures are for standard currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steadystate current.
4. Motor load has an inrush current of 6 times the steady-state current.
Inrush current |
NC |
30 A max. |
NO |
15 A max. |
Approved Standard Ratings
UL/CSA
Model |
Rated voltage |
Current |
Horsepower |
ZE |
125 VAC |
15 A |
1/8HP |
125 VDC |
0.5 A |
--- |
CCC (GB/T14048.5)
Applicable category and ratings |
AC-12 10 A/250 VAC |
Characteristics
Degree of protection |
IP65 *1 |
|
Durability *2 |
Mechanical |
Z[]: 10,000,000 operations min. |
Electrical |
Z[]: 500,000 operations min., for 15 A, 250 VAC resistive load |
|
Operating speed |
Plunger type: 0.01 mm/s to 0.5 m/s |
|
Operating frequency |
Mechanical |
120 operations/min |
Electrical |
20 operations/min |
|
Rated frequency |
50/60 Hz |
|
Insulation resistance |
100 MΩ min. (at 500 VDC) |
|
Contact resistance |
15 mΩ max. (initial value) |
|
Terminal temperature rise |
50°C max. |
|
Dielectric strength |
Between terminals of the same |
1,000 VAC, 50/60 Hz for 1 min |
Between current-carrying |
Z[]: 2,000 VAC, 50/60 Hz for 1 min |
|
Between each terminal and |
Z[]: 2,000 VAC, 50/60 Hz for 1 min |
|
Vibration resistance |
Malfunction |
10 to 55 Hz, 1.5-mm double amplitude *3 |
Shock resistance |
Destruction |
1,000m/s2 max. |
Malfunction |
100 m/s2 max. *4 |
|
Ambient operating temperature |
-10°C to +80°C (with no icing) |
|
Ambient operating humidity |
General-purpose type: 35% to 85%RH |
|
Weight |
Approx. 260 to 280 g |
Note: The above figures are initial values.
1. IP65 for []-N models and IP60 for []-Q models.
2. The values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to 70%RH. Contact your OMRON sales representative for more detailed information on other operating environments.
3. At the operation limit positions.
4. Only for plunger, sealed plunger, roller arm lever, and sealed roller arm lever.
5. Only for crossroller plunger, sealed crossroller plunger, roller plunger, and sealed roller plunger.