Product Category

Enclosed Switches

ZE / ZV / ZV2 / XE / XV / XV2

Long Service Life and Large Breaking Power

Approved Standards

Agency

Standard

File No.

UL

UL508

E76675

CSA

CSA C22.2 No.14

LR45746

CCC (CQC)

GB/T14048.5

Contact your OMRON representative for details.

Note: 1. Models XE, XV, and XV2 are not approved by UL, CSA, and CCC.
          2. Ask your OMRON representative for information on approved models.

Ratings

Model

Rated voltage

Non-inductive load (A)

Inductive load (A)

Resistive load

Lamp load

Inductive load

Motor load

NC

NO

NC

NO

NC

NO

NC

NO

ZE-[]
 ZV-[]
 ZV2-[]

125 VAC
 250 VAC
 480 VAC

15
 15
 10

3
 2.5
 1.5

1.5
 1.25
 0.75

15
 15
 6

5
 3
 1.5

2.5
 1.5
 0.75

125 VDC
 250 VDC

0.5
 0.25

0.5
 0.25

0.05
 0.03

0.05
 0.03

XE-[]
 XV-[]
 XV2-[]

8 VDC
 14 VDC
 30 VDC
 125 VDC
 250 VDC

10
 10
 10
 10
 3

3
 3
 3
 3
 1.5

1.5
 1.5
 1.5
 1.5
 0.75

10
 10
 10
 7.5
 2

10
 10
 10
 6
 1.5

5
 5
 5
 2
 2

2.5
 2.5
 2.5
 2.5
 1.5











Note: 1. The above figures are for standard currents.
          2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
          3. Lamp load has an inrush current of 10 times the steadystate current.
          4. Motor load has an inrush current of 6 times the steady-state current.

Inrush current

NC

30 A max.

NO

15 A max.

Approved Standard Ratings

UL/CSA

Model

Rated voltage

Current

Horsepower

ZE

125 VAC
 250 VAC
 480 VAC

15 A
 15 A
 15 A

1/8HP
 1/4HP

125 VDC
 250 VDC

0.5 A
 0.25 A

---

CCC (GB/T14048.5)

Applicable category and ratings

AC-12 10 A/250 VAC

Characteristics

Degree of protection

IP65 *1

Durability *2

Mechanical

Z[]: 10,000,000 operations min.
 X[]: 1,000,000 operations min.

Electrical

Z[]: 500,000 operations min., for 15 A, 250 VAC resistive load
 X[]: 100,000 operations min., for 10 A, 125 VDC resistive load

Operating speed

Plunger type: 0.01 mm/s to 0.5 m/s
 Lever type: 0.02 mm/s to 0.5 m/s

Operating frequency

Mechanical

120 operations/min

Electrical

20 operations/min

Rated frequency

50/60 Hz

Insulation resistance

100 MΩ min. (at 500 VDC)

Contact resistance

15 mΩ max. (initial value)

Terminal temperature rise

50°C max.

Dielectric strength

Between terminals of the same
 polarity

1,000 VAC, 50/60 Hz for 1 min

Between current-carrying
 metal part and ground

Z[]: 2,000 VAC, 50/60 Hz for 1 min
 X[]: 1,500 VAC, 50/60 Hz for 1 min

Between each terminal and
 non-current-carrying metal part

Z[]: 2,000 VAC, 50/60 Hz for 1 min
 X[]: 1,500 VAC, 50/60 Hz for 1 min

Vibration resistance

Malfunction

10 to 55 Hz, 1.5-mm double amplitude *3

Shock resistance
 *3

Destruction

1,000m/s2 max.

Malfunction

100 m/s2 max. *4
50 m/s2 max. *5

Ambient operating temperature

-10°C to +80°C (with no icing)

Ambient operating humidity

General-purpose type: 35% to 85%RH
 Sealed type: 35% to 95%RH

Weight

Approx. 260 to 280 g

Note: The above figures are initial values.
 1. IP65 for []-N models and IP60 for []-Q models.
 2. The values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to 70%RH. Contact your OMRON sales representative for more detailed information on other operating environments.
 3. At the operation limit positions.
 4. Only for plunger, sealed plunger, roller arm lever, and sealed roller arm lever.
 5. Only for crossroller plunger, sealed crossroller plunger, roller plunger, and sealed roller plunger.