Oil-resistant Proximity Sensors

E2ER / E2ERZ

Proximity Sensors That Withstand Cutting Oil to Reduce Failures Caused by Ingress of Cutting Oil

Standard Proximity Sensors

Size

M8

M12

M18

M30

Shielded

Shielded

Model

E2ER-X2D[]

E2ER-X3D[]

E2ER-X7D[]

E2ER-X10D[]

Sensing distance

2 mm ±10%

3 mm ±10%

7 mm ±10%

10 mm ±10%

Set distance *1

0 to 1.6 mm

0 to 2.4 mm

0 to 5.6 mm

0 to 8 mm

Differential travel

15% max. of sensing distance

10% max. of sensing distance

Detectable object

Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on Catalog.)

Standard sensing object

Iron, 8 × 8 × 1 mm

Iron, 12 × 12 × 1 mm

Iron, 18 × 18 × 1 mm

Iron, 30 × 30 × 1 mm

Response frequency *2

1.5 kHz

1 kHz

0.5 kHz

0.4 kHz

Power supply voltage

10 to 30 VDC, (including 10% ripple (p-p))

Leakage current

0.8 mA max.

Control
 output

Load current

3 to 100 mA

Residual voltage

3 V max. (Load current: 100 mA, Cable length: 2 m)

Indicators

D1 Models: Operation indicator (red), Setting indicator (green)
 D2 Models: Operation indicator (red)

Operation mode
 (with sensing
 object approaching)

D1 Models: NO
 D2 Models: NC
 Refer to the timing charts under I/O Circuit Diagrams on Catalog for details.

Protection circuits

Surge suppressor, Load short-circuit protection

Ambient temperature range

Operating: -25 to 70°C, Storage: -40 to 85°C (with no icing or condensation)

Ambient humidity range

Operating and Storage: 35% to 95% (with no condensation)

Temperature influence

±15% max. of sensing distance
 at 23°C in the temperature
 range of -25 to 70°C

±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C

Voltage influence

±1% max. of sensing distance at rated voltage in the rated voltage ±15% range

Insulation resistance

50 MΩ min. (at 500 VDC) between current-carrying parts and case

Dielectric strength

1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case

Vibration resistance (destruction)

10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions

Shock resistance (destruction)

500 m/s2 10 times
 each in X, Y, and Z directions

1,000 m/s2 10 times each in X, Y, and Z directions

Degree of protection

IP67 (IEC 60529) and IP67G *3 (JIS C 0920 Annex 1)
 Passed OMRON's Oil-resistant Component Evaluation Standards *4
 (Cutting oil type: specified in JIS K 2241:2000, Temperature: 35 °C max.)

Connection method

Pre-wired Models (Standard cable length: 2 m) and Pre-wired Connector Models (Standard cable length: 300 mm)

Weight
 (packed
 state)

Pre-wired Models

Approx. 65 g

Approx. 75 g

Approx. 145 g

Approx. 215 g

Pre-wired Connector Models

Approx. 30 g

Approx. 40 g

Approx. 90 g

Approx. 155 g

Materials

Case

Stainless steel (SUS303)

Nickel-plated brass

Sensing surface

Polybutylene terephthalate (PBT)

Clamping nuts

Nickel-plated brass

Toothed washer

Zinc-plated iron

Accessories

Instruction manual

1. Use the Sensor within the range in which the setting indicator (green LED) is ON (except D2 Models).
 2. The response frequency is an average value.
 Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
 3. The IP67G is the degree of protection which is defined according to the JIS (Japanese Industrial Standards).
 The IP67 indicates the same level of protection as defined by the IEC, and the G indicates that a device has resistance to oil.
 4. The Oil-resistant Component Evaluation Standards are OMRON's own durability evaluation standards.
 The Pre-wired Connector Model meets the degree of protection when it is correctly connected with an XS5[]R Oil-resistant Connector.
 The degree of protection is not satisfied with the part where there is no XS5FR Oil-resistant Connector connected and cable wires are uncovered.
 And as for the Pre-wired Models, the degree of protection is not satisfied with the part where cable wires are uncovered. 

Chip-immune Proximity Sensors

Size

M12

M18

M30

Shielded

Shielded

Model

E2ERZ-X2D[]

E2ERZ-X4D[]

E2ERZ-X8D[]

Sensing distance

2 mm ±10%

4 mm ±10%

8 mm ±10%

Set distance *1

0 to 1.6 mm

0 to 3.2 mm

0 to 6.4 mm

Differential travel

20% max. of sensing distance

Detectable object

Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on Catalog.)

Standard sensing object

Iron, 12 × 12 × 1 mm

Iron, 30 × 30 × 1 mm

Iron, 54 × 54 × 1 mm

Response frequency *2

200 Hz

100 Hz

30 Hz

Power supply voltage

10 to 30 VDC, (including 10% ripple (p-p))

Leakage current

0.8 mA max.

Control
 output

Load current

3 to 100 mA

Residual voltage

3 V max. (Load current: 100 mA, Cable length: 2 m)

Indicators

D1 Models: Operation indicator (red), Setting indicator (green)
 D2 Models: Operation indicator (red)

Operation mode
 (with sensing
 object approaching)

D1 Models: NO
 D2 Models: NC
 Refer to the timing charts under I/O Circuit Diagrams on Catalog for details.

Protection circuits

Surge suppressor, Load short-circuit protection

Ambient temperature range

Operating and Storage: 0 to 50°C (with no icing or condensation)

Ambient humidity range

Operating and Storage: 35% to 95% (with no condensation)

Temperature influence

±20% max. of sensing distance at 23°C in the temperature range of 0 to 50°C

Voltage influence

±2.5% max. of sensing distance at rated voltage in the rated voltage ±10% range

Insulation resistance

50 MΩ min. (at 500 VDC) between current-carrying parts and case

Dielectric strength

1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case

Vibration resistance (destruction)

10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions

Shock resistance (destruction)

1,000 m/s2 10 times each in X, Y, and Z directions

Degree of protection

IP67 (IEC 60529) and IP67G *3 (JIS C 0920 Annex 1)
 Passed OMRON's Oil-resistant Component Evaluation Standards *4
 (Cutting oil type: specified in JIS K 2241:2000, Temperature: 35 ーC max.)

Connection method

Pre-wired Models (Standard cable length: 2 m) and Pre-wired Connector Models (Standard cable length: 300 mm)

Weight
 (packed
 state)

Pre-wired Models

Approx. 75 g

Approx. 145 g

Approx. 215 g

Pre-wired Connector Models

Approx. 40 g

Approx. 90 g

Approx. 155 g

Materials

Case

Nickel-plated brass


Sensing surface

Polybutylene terephthalate (PBT)

Clamping nuts

Zinc-plated iron

Toothed washer

Zinc-plated iron

Accessories

Instruction manual

1. Use the Sensor within the range in which the setting indicator (green LED) is ON (except D2 Models).
 2. The response frequency is an average value.
 Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
 3. The IP67G is the degree of protection which is defined according to the JIS (Japanese Industrial Standards).
 The IP67 indicates the same level of protection as defined by the IEC, and the G indicates that a device has resistance to oil.
 4. The Oil-resistant Component Evaluation Standards are OMRON's own durability evaluation standards.
 The Pre-wired Connector Model meets the degree of protection when it is correctly connected with an XS5[]R Oil-resistant Connector.
 The degree of protection is not satisfied with the part where there is no XS5FR Oil-resistant Connector connected and cable wires are uncovered.
 And as for the Pre-wired Models, the degree of protection is not satisfied with the part where cable wires are uncovered.