Model

E2EZ-X2D[]-N
 E2EZ-X2D[]-M1J
 E2EZ-X2D[]-M1GJ

E2EZ-X4D[]-N
 E2EZ-X4D[]-M1J
 E2EZ-X4D[]-M1GJ

E2EZ-X8D[]-N
 E2EZ-X8D[]-M1J
 E2EZ-X8D[]-M1GJ

E2EZ-X4C1
 E2EZ-X4B1
 E2EZ-X4B1-M1J

E2EZ-X8C1
 E2EZ-X8B1
 E2EZ-X8B1-M1J

Sensing distance

2 mm ±10%

4 mm ±10%

8 mm ±10%

4 mm ±10%

8 mm ±10%

Set distance *1

0 to 1.6 mm

0 to 3.2 mm

0 to 6.4 mm

0 to 3.2 mm

0 to 6.4 mm

Differential travel

20% max. of sensing distance

Detectable object

Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering
 Data on Data Sheet.)

Standard sensing
 object

Iron, 12 × 12 × 1 mm

Iron, 30 × 30 × 1 mm

Iron, 54 × 54 × 1 mm

Iron, 30 ×
 30 × 1 mm

Iron, 54 ×
 54 × 1 mm

Response
 frequency *2

200 Hz

100 Hz

30 Hz

12 Hz

8 Hz

Power supply volt-
 age (operating
 voltage range)

12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.

12 to 24 VDC (10 to 30 VDC),
 ripple (p-p): 10% max.

Current
 consumption

---

15 mA max.

Leakage current

0.8 mA max.

---

Control
 output

Load
 current

3 to 100 mA max.

NPN open-collector output/
 PNP open-collector output
 100 mA max. at 12 VDC (30 VDC max.)
 200 mA max. at 24 VDC (30 VDC max.)

Residual
 voltage

3 V max. (Load current: 100 mA, Cable length: 2 m)

2 V max. (Load current: 200 mA,
 Cable length: 2 m)

Indicators

D1 Models: Operation indicator (red), Setting indicator (green)
 D2 Models: Operation indicator (red)

Detection indicator (red)

Operation mode
 (with sensing ob-
 ject approaching)

D1 Models: NO
 D2 Models: NC
 For details, refer to the Timing chart on Data Sheet.

NO
 For details, refer to the
 Timing chart on Data Sheet.

Protection
 circuits

Load short-circuit protection, Surge suppressor

Load short-circuit protection,
 Reverse polarity protection,
 Surge suppressor

Ambient
 temperature range

Operating/Storage: 0 to 50°C (with no icing or condensation)

Ambient
 humidity range

Operating/Storage: 35% to 95% (with no condensation)

Temperature
 influence

±20% max. of sensing distance at 23°C in the temperature range of 0 to 50°C

Voltage influence

±2.5% max. of sensing distance at rated voltage in the rated voltage ±10% range

Insulation
 resistance

50 MΩ min. (at 500 VDC) between current-carrying parts and case

Dielectric
 strength

1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case

Vibration
 resistance

Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions

Shock resistance

Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions

Degree of
 protection

IEC 60529 IP67, in-house standards: oil-resistant

Connection
 method

Pre-wired Models (Standard cable length: 2 m) and Pre-wired Connector Models

Weight
 (packed state)

E2EZ-X2D[]-N:
 Approx. 70 g
 E2EZ-X2D[]-M1J:
 Approx. 40 g
 E2EZ-X2D[]-M1GJ:
 Approx. 40 g

E2EZ-X4D[]-N:
 Approx. 160 g
 E2EZ-X4D[]-M1J:
 Approx. 90 g
 E2EZ-X4D[]-M1GJ:
 Approx. 90 g

E2EZ-X8D[]-N:
 Approx. 220 g
 E2EZ-X8D[]-M1J:
 Approx. 160 g
 E2EZ-X8D[]-M1GJ:
 Approx. 160 g

Approx. 170 g

Approx. 270 g

Materi-
 als

Case

Nickel-plated brass

Sensing
 surface

PBT

Heat-resistant ABS

Clamping
 nuts

Zinc-plated iron

Toothed
 washer

Zinc-plated iron

Accessories

Instruction manual

1. Use the Sensor within the range in which the green indicator is ON.
 2. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a
        distance of twice the standard sensing object, and a set distance of half the sensing distance.