Enclosed Switch
D4C
Sealed, Compact, and Slim-bodied Switch Offers Choice of Many Actuators
Approved Standards
Agency |
Standard |
File No. |
TÜV Product Service |
EN60947-5-1 |
*1, 3 |
UL |
UL508 |
E76675 *2 |
CSA |
CSA C22.2 No.14 |
LR45746 *2 |
CCC(CQC) |
GB/T14048.5 |
*3 |
1. Excluding weather-resistant models, only models with VCTF oil-resistant cables and pre-wired models are certified. (Contact your OMRON representative for the model numbers.)
Models with VCTF oil-resistant cables and pre-wired models (125 VAC) are certified for CE Marking.
2. SJT(O)-cable models only. (Applicable only to models listed on Lineup.)
3. Ask your OMRON representative for information on approved models.
Ratings
Standard Model
Rated voltage |
Non-inductive load (A) |
Inductive load (A) |
|||||||
Resistive load |
Lamp load |
Inductive load |
Motor load |
||||||
NC |
NO |
NC |
NO |
NC |
NO |
NC |
NO |
||
125 VAC |
5 (0.1) |
1.5 |
0.7 |
3 |
2.5 |
1.3 |
|||
8 VDC |
5 (0.1) |
2 |
5 |
4 |
3 |
||||
0.4 |
|||||||||
Inrush current |
NC |
20 A max. |
|||||||
NO |
10 A max. |
||||||||
Note: 1. The values given on the top are steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp loads have an inrush current of 10 times the steady-state current.
4. Motor loads have an inrush current of 6 times the steady-state current.
5. The values "0.1" given in parentheses are for micro load models.
Pre-wired Model
Rated voltage |
Non-inductive load (A) |
Inductive load (A) |
||||||
Resistive load |
Lamp load |
Inductive load |
Motor load |
|||||
NC |
NO |
NC |
NO |
NC |
NO |
NC |
NO |
|
125 VAC |
1 |
1 |
1 |
0.7 |
1 |
1 |
1 |
1 |
30 VDC |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
Approved Standard Ratings
TÜV (EN60947-5-1), CCC (GB/T14048.5)
Model |
Applicable category and ratings |
I the |
D4C-1[][][] |
AC-15 2 A/250 V |
5 A |
D4C-2[][][] |
AC-15 2 A/125 V |
5 A |
D4C-3[][][] |
DC-12 2 A/30 V |
4 A |
D4C-4[][][] |
AC-14 0.1 A/125 V |
0.5 A |
D4C-5[][][] |
AC-14 0.1 A/125 V |
0.5 A |
D4C-6[][][] |
DC-12 0.1 A/30 V |
0.5 A |
UL/CSA
B300 (D4C-16[][], -17[][])
B150 (D4C-26[][], -27[][])
B300
Rated voltage |
Carry current |
Current (A) |
Volt-amperes (VA) |
||
Make |
Break |
Make |
Break |
||
120 VAC |
5 A |
30 |
3 |
3,600 |
360 |
B150
Rated voltage |
Carry current |
Current (A) |
Volt-amperes (VA) |
||
Make |
Break |
Make |
Break |
||
120 VAC |
5 A |
30 |
3 |
3,600 |
360 |
Characteristics
Degree of protection |
IP67 |
|
Durability *1 |
Mechanical *3 |
10,000,000 operations min. |
Electrical *2 |
200,000 operations min. (5 A at 125 VAC, resistive load) |
|
Operating speed |
0.1 mm/s to 0.5 m/s (in case of plunger) |
|
Operating frequency |
Mechanical |
120 operations/min |
Electrical |
30 operations/min |
|
Rated frequency |
50/60 Hz |
|
Insulation resistance |
100 MΩ min. (at 500 VDC) |
|
Contact resistance (initial) |
250 mΩ max. (initial value with 2-m VCTF cable) |
|
Dielectric strength |
Between terminals of the same polarity |
1,000 VAC, 50/60 Hz for 1 min |
Between current-carrying metal part |
1,500 VAC, 50/60 Hz for 1 min |
|
Between each terminal and non- |
1,500 VAC, 50/60 Hz for 1 min |
|
Rated insulation voltage (Ui) |
300 V (EN60947-5-1) *5 |
|
Pollution degree (operating environment) |
3 (EN60947-5-1) |
|
Short-circuit protective device (SCPD) |
10 A fuse type gI or gG (IEC60269) |
|
Conditional short-circuit current |
100 A (EN60947-5-1) |
|
Conventional enclosed thermal current (I the) |
5 A, 4 A, 0.5 A (EN60947-5-1) |
|
Protection against electric shock |
Class I (with grounding wire) *6 |
|
Vibration resistance |
Malfunction |
10 to 55 Hz, 1.5-mm double amplitude *4 |
Shock resistance |
Destruction |
1,000 m/s2 max. |
Malfunction |
500 m/s2 max. *4 |
|
Ambient operating temperature |
-10°C to +70°C (with no icing) |
|
Ambient operating humidity |
35% to 95%RH |
|
Weight (D4C-1202) |
With 3-m VCTF cable: 360 g |
Note: The above figures are initial values.
1. The values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to 70%RH. Contact your OMRON sales representative for more detailed information on other operating environments.
2. Pre-wired Models: 1,000,000 operations min. (DC specifications, switching current: 0.1 A)
3. Outdoor specifications: 500,000 operations min.
4. Excluding Plastic Rods.
5. Pre-wired models: 250 V
6. Pre-wired models: class III