Product Category

D4C

Enclosed Switch

D4C

Sealed, Compact, and Slim-bodied Switch Offers Choice of Many Actuators

Approved Standards

Agency

Standard

File No.

TÜV Product Service

EN60947-5-1

*1, 3

UL

UL508

E76675 *2

CSA

CSA C22.2 No.14

LR45746 *2

CCC(CQC)

GB/T14048.5

*3

1. Excluding weather-resistant models, only models with VCTF oil-resistant cables and pre-wired models are certified. (Contact your OMRON representative for the model numbers.)
 Models with VCTF oil-resistant cables and pre-wired models (125 VAC) are certified for CE Marking.
 2. SJT(O)-cable models only. (Applicable only to models listed on Lineup.)
 3. Ask your OMRON representative for information on approved models.

Ratings

Standard Model

Rated voltage

Non-inductive load (A)

Inductive load (A)

Resistive load

Lamp load

Inductive load

Motor load

NC

NO

NC

NO

NC

NO

NC

NO

125 VAC
 250 VAC

5 (0.1)
 5

1.5
 1

0.7
 0.5

3
 2

2.5
 1.5

1.3
 0.8

8 VDC
 14 VDC
 30 VDC
 125 VDC
 250 VDC

5 (0.1)
 5 (0.1)
 4 (0.1)
 0.4
 0.2

2
 2
 2
 0.05
 0.03

5
 4
 3

4
 4
 3

3
 3
 3
 0.05
 0.03

0.4
 0.2

Inrush current

NC

20 A max.

NO

10 A max.











Note: 1. The values given on the top are steady-state currents.
            2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
            3. Lamp loads have an inrush current of 10 times the steady-state current.
            4. Motor loads have an inrush current of 6 times the steady-state current.
            5. The values "0.1" given in parentheses are for micro load models.

Pre-wired Model 

Rated voltage

Non-inductive load (A)

Inductive load (A)

Resistive load

Lamp load

Inductive load

Motor load

NC

NO

NC

NO

NC

NO

NC

NO

125 VAC

1

1

1

0.7

1

1

1

1

30 VDC

1

1

1

1

1

1

1

1

Approved Standard Ratings                              

TÜV (EN60947-5-1), CCC (GB/T14048.5)

Model

Applicable category and ratings

I the

D4C-1[][][]

AC-15 2 A/250 V
 DC-12 2 A/30 V

5 A
 4 A

D4C-2[][][]

AC-15 2 A/125 V

5 A

D4C-3[][][]

DC-12 2 A/30 V

4 A

D4C-4[][][]

AC-14 0.1 A/125 V
 DC-12 0.1 A/30 V

0.5 A
 0.5 A

D4C-5[][][]

AC-14 0.1 A/125 V

0.5 A

D4C-6[][][]

DC-12 0.1 A/30 V

0.5 A

UL/CSA

B300 (D4C-16[][], -17[][])
 B150 (D4C-26[][], -27[][])
 B300

Rated voltage

Carry current

Current (A)

Volt-amperes (VA)

Make

Break

Make

Break

120 VAC
 240 VAC

5 A

30
 15

3
 1.5

3,600
 3,600

360
 360

B150

Rated voltage

Carry current

Current (A)

Volt-amperes (VA)

Make

Break

Make

Break

120 VAC

5 A

30

3

3,600

360

Characteristics

Degree of protection

IP67

Durability *1

Mechanical *3

10,000,000 operations min.

Electrical *2

200,000 operations min. (5 A at 125 VAC, resistive load)

Operating speed

0.1 mm/s to 0.5 m/s (in case of plunger)
 1 mm/s to 1 m/s (in case of roller lever)

Operating frequency

Mechanical

120 operations/min

Electrical

30 operations/min

Rated frequency

50/60 Hz

Insulation resistance

100 MΩ min. (at 500 VDC)

Contact resistance (initial)

250 mΩ max. (initial value with 2-m VCTF cable)
 300 mΩ max. (initial value with 3-m VCTF cable)
 400 mΩ max. (initial value with 5-m VCTF cable)

Dielectric strength

Between terminals of the same polarity

1,000 VAC, 50/60 Hz for 1 min

Between current-carrying metal part
 and ground

1,500 VAC, 50/60 Hz for 1 min
 Uimp: 2.5 kV (EN60947-5-1)

Between each terminal and non-
 current-carrying metal part

1,500 VAC, 50/60 Hz for 1 min
 Uimp: 2.5 kV(EN60947-5-1)

Rated insulation voltage (Ui)

300 V (EN60947-5-1) *5

Pollution degree (operating environment)

3 (EN60947-5-1)

Short-circuit protective device (SCPD)

10 A fuse type gI or gG (IEC60269)

Conditional short-circuit current

100 A (EN60947-5-1)

Conventional enclosed thermal current (I the)

5 A, 4 A, 0.5 A (EN60947-5-1)

Protection against electric shock

Class I (with grounding wire) *6

Vibration resistance

Malfunction

10 to 55 Hz, 1.5-mm double amplitude *4

Shock resistance

Destruction

1,000 m/s2 max.

Malfunction

500 m/s2 max. *4

Ambient operating temperature

-10°C to +70°C (with no icing)

Ambient operating humidity

35% to 95%RH

Weight (D4C-1202)

With 3-m VCTF cable: 360 g
 With 5-m VCTF cable: 540 g

Note: The above figures are initial values.
 1. The values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to 70%RH. Contact your OMRON sales representative for more detailed information on other operating environments.
 2. Pre-wired Models: 1,000,000 operations min. (DC specifications, switching current: 0.1 A)
 3. Outdoor specifications: 500,000 operations min.
 4. Excluding Plastic Rods.
 5. Pre-wired models: 250 V
 6. Pre-wired models: class III