Ratings
Rated voltage |
Non-inductive load (A) |
Inductive load (A) |
||||||
Resistive load |
Lamp load |
Inductive load |
Motor load |
|||||
NC |
NO |
NC |
NO |
NC |
NO |
NC |
NO |
|
125 VAC |
1 |
1 |
1 |
0.7 |
1 |
1 |
1 |
1 |
30 VDC |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
Note: 1. The above current ratings are for steady-state current.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp loads have an inrush current of 10 times the steady-state current.
4. Motor loads have an inrush current of 6 times the steady-state current.
D4CC-3, D4CC-4, 1 A at 30 VDC
Inrush current |
NC |
5 A max. |
NO |
2.5 A max. |
Characteristics
Degree of protection |
IP67 |
|
Durability *1 |
Mechanical |
10,000,000 operations min. |
Electrical |
200,000 operations min. (1 A at 125 VAC, resistive load) |
|
Operating speed |
0.1 mm/s to 0.5 m/s (in case of plunger) |
|
Operating |
Mechanical |
120 operations/min |
Electrical |
30 operations/min |
|
Rated frequency |
50/60 Hz |
|
Insulation resistance |
100 MΩ min. (at 500 VDC) |
|
Contact resistance (initial) |
100 mΩ max. |
|
Dielectric |
Between terminals of same polarity |
1,000 VAC, 50/60 Hz for 1 min |
Between current-carrying metal |
1,500 VAC, 50/60 Hz for 1 min |
|
Between each termi-nal and non- |
1,500 VAC, 50/60 Hz for 1 min |
|
Vibration |
Malfunction |
10 to 55 Hz, 1.5-mm double amplitude *2 |
Shock |
Destruction |
1,000 m/s2 max. |
Malfunction |
500 m/s2 max. *2 |
|
Ambient operating temperature |
-10°C to +70°C (with no icing) |
|
Ambient operating humidity |
35% to 95%RH |
|
Weight |
Approx. 120 g (in the case of D4CC-1002) |
Note: The above figures are initial values.
1. The values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to 70%RH. Contact your OMRON sales representative for more detailed information on other operating environments.
2. Excluding plastic rod models.
Leakage Current for Switches with Indicators
The leakage current and resistance of Switches with indicators are as follows:
Item Model |
D4CC-2[][][] |
D4CC-4[][][] |
Voltage |
125 VAC |
30 VDC |
Leakage current |
1.0 mA |
1.0 mA |
Resistive value |
150 k Ω |
30 k Ω |