Product Category

Proximity Sensor Ideal for High Temperatures and Cleaning Processes

E2EH

Proximity Sensor Ideal for the Food and Beverage Industry

E2EH-X[]D[] DC 2-Wire Models

Size

M12

M18

M30

Shielded

Shielded

Model

E2EH-X3D[]

E2EH-X7D[]

E2EH-X12D[]

Sensing distance

3 mm

7 mm

12 mm

Set distance *1

0 to 2.4 mm

0 to 5.6 mm

0 to 9.6 mm

Differential travel

15% max. of sensing distance

Detectable object

Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Datasheet.)

Standard sensing object

Iron, 12 × 12 × 1 mm

Iron 21 × 21 × 1 mm

Iron 36 × 36 × 1 mm

Response frequency *2

500 Hz

300 Hz

100 Hz

Power supply voltage (operating
 voltage range)

12 to 24 VDC, ripple (p-p): 10% max.
 (10 to 32 VDC)

Leakage current

0.8 mA max.

Control output

Load current

3 to 100 mA


Residual voltage *3

Polarity Models: 3 V max.
 No polarity Models: E2EH-X[]D[]-T: (5 V max. *3 (Load current: 100 mA, Cable length 2 m)

Indicators

D1 Models: Operation indicator (red), Setting indicator (yellow)
 D2 Models: Operation indicator (yellow)

Operation mode (with sensing object
 approaching)

D1 Models: NO
 D2 Models: NC
 Refer to Datasheet.

Protection circuits

Surge suppressor, Load short-circuit protection

Ambient temperature range

Operating: 0 to 100°C
 Storage: -25 to 70° (with no icing or condensation)

Ambient humidity range

35% to 95%

Temperature influence

±10% max. of sensing distance at 23°C in the temperature range of 0 to 70°C.
 ±15% max. of sensing distance at 23°C in the temperature range of 70 to 100°C.

Voltage influence

± 10% max. of sensing distance at rated voltage in the 15% rated voltage range.

Insulation resistance

50 MΩ min. (at 500 VDC) between current-carrying parts and case

Dielectric strength

1,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case

Vibration resistance

Destruction: 10 to 55 Hz 1.5-mm double amplitude for 2 hours each in X, Y and Z directions

Shock resistance

Destruction: 1,000 m/s2, 10 times each in X, Y and Z directions

Degree of protection

IEC IP67, DIN 40050-9 IP69K *4

Connection method

Pre-wired Models (Standard cable length 2 m), Connector Models

Weight
 (packed state)

Pre-wired Models

Approx. 80 g

Approx. 145 g

Approx. 220 g

Connector Models

Approx. 30 g

Approx. 55 g

Approx. 125 g

Materials

Case, clamping nut

Stainless steel (SUS316L)

Sensing surface

PBT

Cable

Heat-resistant PVC cable (Pre-wired model)

Accessories

Instruction manual

1. Use the yellow indicator on D1 Models as a guide.
 2. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
 3. The residual voltage of each E2EH-X@D@ DC 2-Wire Model is 5 V. When connecting to a device, make sure that the device can withstand the residual voltage. (Refer to Data Sheet.)
 4. IP69K Degree of Protection Specification IP69K is a protection standard against high temperature and high-pressure water defined in the German standard DIN 40050,
 Part 9. The test piece is sprayed with water at 80°C at a water pressure of 80 to 100 BAR using a specified nozzle shape at a rate of 14 to 16 liters/min.
 The distance between the test piece and nozzle is 10 to 15 cm, and water is sprayed horizontally for 30 seconds each at 0°, 30°, 60°, and 90° while rotating the test piece on a horizontal plane. 

 image

E2EH-X[]C[]/B[] DC 3-Wire Models

Size

M12

M18

M30

Shielded

Shielded

Model

E2EH-X3C[]/B[]

E2EH-X7C[]/B[]

E2EH-X12C[]/B[]

Sensing distance

3 mm±10%

7 mm±10%

12 mm±10%

Set distance *1

0 to 2.4 mm

0 to 5.6 mm

0 to 9.6 mm

Differential travel

15% max. of sensing distance

Detectable object

Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Datasheet.)

Standard sensing object

Iron, 12 × 12 × 1 mm

Iron 21 × 21 × 1 mm

Iron 36 × 36 × 1 mm

Response frequency *2

500 Hz

300 Hz

100 Hz

Power supply voltage (operating
 voltage range)

12 to 24 VDC, ripple (p-p): 10% max.
 (10 to 32 VDC)

Current consumption

10 mA max.

Control output

Load current

100 mA max.

Residual voltage

2 V max. (Load current: 100 mA, Cable length 2 m)

Indicators

Operation indicator (yellow)

Operating mode
 (with sensing object approaching)

C1 Models: NO
 C2 Models: NC
 B1 Models: NO
 B2 Models: NC
 Refer to Datasheet.

Protection circuits

Power supply reverse polarity protection, Surge suppressor, Load short-circuit protection, Reversed output polarity protection

Ambient temperature range

Operating: 0 to 100°C
 Storage: -25 to 70°C (with no icing or condensation)

Ambient humidity range

35% to 95%

Temperature influence

±10% max. of sensing distance at 23°C in the temperature range of 0 to 70°C.
 ±15% max. of sensing distance at 23°C in the temperature range of 70 to 100°C.

Voltage influence

10% max. of sensing distance at rated voltage in the 15% rated voltage range.

Insulation resistance

50 MΩ min. (at 500 VDC) between current-carrying parts and case

Dielectric strength

1,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case

Vibration resistance

Destruction: 10 to 55 Hz 1.5-mm double amplitude for 2 hours each in X, Y and Z directions

Shock resistance

Destruction: 1,000 m/s2, 10 times each in X, Y and Z directions

Degree of protection

IEC IP67, DIN 40050-9 IP69K

Connection method

Pre-wired Models (Standard cable length 2 m), Connector Models

Weight
 (packed
 state)

Pre-wired Models

Approx. 80 g

Approx. 145 g

Approx. 220 g

Connector Models

Approx. 30 g

Approx. 55 g

Approx. 125 g

Materials

Case,
 clamping nut

Stainless steel (SUS316L)

Sensing surface

PBT

Cable

Heat-resistant PVC cable (Pre-wired Model)

Accessories

Instruction manual

1. The response frequency is an average value.
        Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.

Resistance to Detergents, Disinfectants, and Chemicals

  • Performance is assured for typical detergents and disinfectants, but performance may not be maintained for some detergents and disinfectants. Refer to the following table when using these agents.
  • The E2EH passed testing for resistance to detergents and disinfectants performed using the items in the following table. Refer to this table when considering use of detergents and disinfectants.

Category

Product name

Concentration

Temperature

Time

Chemical

Sodium hydroxide (NaOH)

1.5%

70 ° C

240h

Potassium hydroxide (KOH)

1.5%

70 ° C

240h

Phosphoric acid (H3PO4)

2.5%

70 ° C

240h

Sodium hypochlorite (NaClO)

0.3%

25 ° C

240h

Hydrogen peroxide (H2O2)

6.5%

25 ° C

240h

Alkaline foam detergent

P3-topax-66s (Manufactured by Ecolab)

3.0%

70 ° C

240h

Acidic foam detergent

P3-topax-56 (Manufactured by Ecolab)

5.0%

70 ° C

240h

Disinfectant

P3-oxonia active 90 (Manufactured by Ecolab)

1.0%

25 ° C

240h

Test Conditions

image

After the test is completed, check that no problems exist with the following product characteristics.
 (1) Appearance (no damage that will affect the product characteristics)
 (2) Operation Check (ON/OFF)
 (3) Insulation resistance: 50 MΩ min. (at 500 VDC)
 (4) Dielectric strength (1,000 VAC for 1 minute)
 (5) Water resistance (IP67)