Miniature Limit Switch
HL-5000
Economical, Miniature Limit Switch Boasting Rigid Construction
Approved Standards
Agency |
Standard |
File No. |
CCC (CQC) |
GB/T14048.5 |
- |
Ratings
Rated voltage |
Non-inductive load (A) |
Inductive load (A) |
||||||
Resistive load |
Lamp load |
Inductive load |
Motor load |
|||||
NC |
NO |
NC |
NO |
NC |
NO |
NC |
NO |
|
125 VAC |
5 |
1.5 |
0.7 |
3 |
2 |
1 |
||
12 VDC |
5 |
3 |
4 |
3 |
||||
0.4 |
0.2 |
- |
- |
- |
||||
Note: 1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.
Inrush current |
NC |
24 A max. |
NO |
12 A max. |
Approved Standard Ratings
CCC (GB/T14048.5)
Applicable category and ratings |
AC-15 3 A/250 VAC |
Characteristics
Degree of protection |
IP65 |
|
Durability * |
Mechanical |
10,000,000 operations min. (under rated conditions) |
Electrical |
See the following Electrical Durability. |
|
Operating speed |
5 mm/s to 0.5 m/s |
|
Operating frequency |
Mechanical |
120 operations/min |
Electrical |
30 operations/min |
|
Insulation resistance |
100 MΩ min. (at 500 VDC) |
|
Contact resistance |
25 mΩ max. (initial value) |
|
Dielectric strength |
1,000 VAC, 50/60 Hz for 1 min between terminals of the same polarity |
|
1,500 VAC, 50/60 Hz for 1 min between current-carrying metal parts and ground |
||
1,500 VAC, 50/60 Hz for 1 min between each terminal and non-current-carrying metal part |
||
Rated frequency |
50/60 Hz |
|
Vibration resistance |
Malfunction |
10 to 55 Hz, 1.5-mm double amplitude |
Shock resistance |
Destruction |
1,000 m/s2 max. |
Malfunction |
300 m/s2 max. |
|
Ambient operating temperature |
-5°C to +65°C (with no icing) |
|
Ambient operating humidity |
35% to 95%RH |
|
Weight |
Approx. 130 to 190 g |
Note: 1. The above figures are initial values.
2. The above characteristics may vary depending on the model.
* The values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to 70%RH.